Replace a Dual Flash Carrier
Use this procedure to replace the entire failed Dual Flash drive carrier in your HPE storage array or expansion shelf.
Time required: |
5 to 10 minutes |
Parts required: |
Replacement drive carrier ordered from HPE |
Information required: |
|
Tools required: |
|
Support contact: |
See Support. |
HPE recommends using the Maintenance Window functionality within the HPE InfoSight portal to inform HPE Support of upcoming maintenance windows.
Refer to https://infosight.hpe.com/dashboards/nimble/wellness/maintenance-windows for more information.
You can disable automated support case generation during planned maintenance from the Manage Maintenance Windows page. After a maintenance window is set, no further communication with HPE Support is required.
Before you attempt to replace the failed drive carrier:
- Do not remove the drive carrier or individual SSD slots from the drive carrier until you are ready to install the replacement.
- Determine that the drive carrier has failed before making the
replacement.
To identify a failed drive carrier:
- LED on the carrier itself is solid red
- Event appears in the Events list
- Receipt of an alert email from the array
- Verify that the replacement drive carrier matches the part shown on the RMA work order.
- Use the same type and size replacement drive carrier as the old drive
carrier (SSD dual flash carrier).
The A and B drive sled label may vary in appearance or be upside down when the new drive carrier is properly oriented.