Replace a DC Power Supply
Time required: |
10 to 15 minutes |
Parts required: |
Replacement DC power supply ordered from HPE |
Information required: |
|
Tools required: |
|
Support contact: |
See Support. |
HPE recommends using the Maintenance Window functionality within the HPE InfoSight portal to inform HPE Support of upcoming maintenance windows.
Refer to https://infosight.hpe.com/dashboards/nimble/wellness/maintenance-windows for more information.
You can disable automated support case generation during planned maintenance from the Manage Maintenance Windows page. After a maintenance window is set, no further communication with HPE Support is required.
A PSU with an amber LED may have a fault. But an amber LED also indicates:
- The external power is switched off with the DC power connected
- The power supply is not properly seated in its slot
- The array is powered off
- A power supply internal fault has occurred
Verify that the power cord is plugged in, then check for and correct these conditions before you assume that the PSU in your HPE storage array needs to be replaced.
Before you attempt to replace a power supply:
- Do not remove the PSU until you are ready to install the replacement
- Never unplug or unseat both PSUs at the same time
- Use only UL-approved power cords
Use this procedure to replace a failed DC power supply unit (PSU) on your HPE storage array or expansion shelf.
Power supplies are replaced as a complete unit. One PSU can adequately power the array while the other PSU is being replaced.
The procedure is the same for all HPE Nimble Storage arrays.