Upgrade the Controller
Time required: |
Up to 90 minutes for the new controller to appear in the UI |
Parts required: |
New controllers ordered from HPE |
Information required: |
|
Tools required: |
|
Support contact: | See Support. |
Refer to the following table to determine what models you can upgrade your array model to.
Original Model | To New Model |
---|---|
CS1000H (min 720GB cache) | CS3000 NOTE: The CS1000H can only be upgraded to a CS3000. No further controller upgrades are supported.
|
CS1000 (min 720GB cache) | CS3000, CS5000, CS7000 |
CS3000 (min 720GB cache) | CS5000, CS7000 |
CS5000 (min 720GB cache) | CS7000 |
SF100 (min 720GB cache) | SF300 |
- The minimum cache required to support the controller upgrade is 720GB. If your array does not have 720GB of cache capacity, you must upgrade the cache before proceeding with the controller upgrade. Refer to the Cache Upgrade Guide.
- If you have a CS1000H model array, you must fully populate the 11 empty hard drive slots before upgrading to CS3000 controllers. Refer to the Drive Upgrade Guide (HDD).
HPE recommends using the Maintenance Window functionality within the HPE InfoSight portal to inform HPE Support of upcoming maintenance windows.
Refer to https://infosight.hpe.com/dashboards/nimble/wellness/maintenance-windows for more information.
You can disable automated support case generation during planned maintenance from the Manage Maintenance Windows page. After a maintenance window is set, no further communication with HPE Support is required.
- If one controller fails, the other controller takes over. The array can function with one healthy controller while the new one is installed.
- Upgrade controllers are shipped with empty PCIe cages installed. Before installing the new controller, you must move the PCIe cage from the existing controller and install it into the new controller.
- Replace the array controller if any of its components, such as the NVDIMM, have failed. If replacing a controller, see Replace a Controller.
- If upgrading SSDs, see Upgrade SSDs.
- If upgrading NICs or FC HBAs, see Upgrade NICs or Fibre Channel HBAs.
Before you attempt to install the controller:
- For CS1000, CS3000, and CS5000 models, ensure that the array is updated to NimbleOS 3.7.0.0 or later.
- For SF100 models, ensure that the array is updated to NimbleOS 4.2.0.0 or later.
- Do not remove the existing controller until you are ready to install the upgrade.
- Determine which controller to upgrade before installation.
- Determine the model, NimbleOS version running on the array, and the state of the controllers. See Find the Model Number of an Array or Expansion Shelf Using the GUI and Determine the Operating State of the Controllers Using the GUI.
Use this procedure to upgrade the controllers in your HPE storage array.
Return both replaced controllers using the instructions that came with the upgrade kit.