Replace an AC Power Supply
Time required: | 5 to 10 minutes |
Parts required: | Replacement AC power supply ordered from HPE |
Information required: |
|
Support contact: |
See Support. |
HPE recommends using the Maintenance Window functionality within the HPE InfoSight portal to inform HPE Support of upcoming maintenance windows.
Refer to https://infosight.hpe.com/dashboards/nimble/wellness/maintenance-windows for more information.
You can disable automated support case generation during planned maintenance from the Manage Maintenance Windows page. After a maintenance window is set, no further communication with HPE Support is required.
Before you attempt to replace a power supply:
- Do not remove the PSU until you are ready to install the replacement
- Never unplug or unseat both PSUs at the same time
- Both PSUs in a controller or expander must be the same
- Use only UL-approved power cords
Use this procedure to replace a failed AC power supply unit (PSU) on your HPE storage array or expansion shelf.